home *** CD-ROM | disk | FTP | other *** search
/ Spec Disk 1998 Spring 4.0 / Spec Disk 1998 Spring 4.0.iso / text / 08405aci.txt < prev    next >
Text File  |  1998-06-10  |  16KB  |  396 lines

  1.                          SECTION 08405
  2.  
  3.                   METAL-FRAMED CLAD ENTRANCES
  4. NOTE ** ACI Distribution metal framed clad entrances.
  5. NOTE **
  6. NOTE ** This section is based on products fabricated by ACI
  7.         Distribution, which has locations at the following
  8.         addresses:
  9. NOTE **
  10. NOTE **     West of Rocky Mountains:
  11. NOTE **         9010 S. Norwalk Boulevard
  12. NOTE **         Santa Fe Springs CA 90670
  13. NOTE **         Tel:  (800) 285-3677
  14. NOTE **         Tel:  (562) 908-8893
  15. NOTE **         Fax:  (562) 695-8496
  16. NOTE **
  17. NOTE **     East of Rocky Mountains:
  18. NOTE **         129000 Nicholson Road
  19. NOTE **         Farmers Branch TX 75234
  20. NOTE **         Tel:  (800) 284-4527
  21. NOTE **         Tel:  (972) 484-3691
  22. NOTE **         Fax:  (972) 247-6457.
  23. NOTE **
  24. NOTE ** ACI Distribution offers a variety of architectural
  25.         building products, including tempered glass
  26.         handrail assemblies, metal-framed clad entrances,
  27.         and all-glass entrances.
  28. NOTE **
  29. NOTE ** SECTION 08405 - METAL FRAMED CLAD ENTRANCES,
  30.         Copyright 1997, The Architect's Catalog, Inc.
  31.  
  32.  
  33. PART 1  GENERAL
  34.  
  35. 1.1 SECTION INCLUDES
  36. NOTE ** Delete items below not required for project.
  37.  
  38.     A.  Metal Framed Clad Entrances.
  39.  
  40. 1.2 RELATED SECTIONS
  41. NOTE ** Delete any sections below not relevant to this
  42.         project; add others as required.
  43.     A.  Section 08410 - Metal-Framed Storefronts.
  44.  
  45.     B.  Section 08710 - Door Hardware.
  46.  
  47.     C.  Section 08800 - Glazing.
  48.  
  49. 1.3 REFERENCES
  50. NOTE ** Delete references from the list below that are not
  51.         actually required by the text of the edited
  52.         section.
  53.  
  54.     A.  ASTM A 666 - Standard Specification for Austenitic
  55.         Stainless Steel Sheet, Strip, Plate, and Flat Bar.
  56.  
  57.     B.  ASTM B 455 - Standard Specification for Copper-Zinc-Lead
  58.         (Leaded Brass) Extruded Shapes.
  59.  
  60.     C.  NAAMM Metal Finishes Manual; National Association of
  61.         Architectural Metal Manufacturers.
  62.  
  63. 1.4 SUBMITTALS
  64.  
  65.     A.  Submit under provisions of Section 01300.
  66.  
  67.     B.  Product Data:  Fabricator's descriptive literature for
  68.         specified components.
  69.  
  70.     C.  Shop Drawings:  Dimensioned drawings as follows:
  71.         1.  Plans:  Indicate layout of entrance assemblies.
  72.         2.  Elevations:
  73.             a.  Appearance of entrance layouts; include locations
  74.                 of visible seams in metal cladding.
  75.             b.  Locations and identification of manufacturer-
  76.                 supplied door hardware.
  77.             c.  Locations and sizes of cut-outs and drilled holes
  78.                 for other door hardware.
  79.         3.  Details:
  80.             a.  Interface with adjacent construction; include
  81.                 requirements for support and bracing at openings.
  82.             b.  Cross-section profiles of metal members,
  83.                 including mullions, perimeter framing, and door
  84.                 stiles and rails; include cladding details and
  85.                 seam locations.
  86.             c.  Installation details.
  87.             d.  Appearance of fabricator-supplied door hardware.
  88.         4.  Schedule:  Listing of each type component in entrance
  89.             assemblies, cross-referenced to shop drawing plans,
  90.             elevations, and details.
  91. NOTE ** Delete the following paragraph if specifying custom
  92.         colors or finishes, or if selections are specified
  93.         in this section.
  94.  
  95.     D.  Selection Samples:  Two sets, representing fabricator's
  96.         full range of available metal materials and finishes.
  97.  
  98.     E.  Verification Samples:  Two samples, minimum size 2 inches
  99.         (50 mm) by 3 inches (76 mm), representing actual material
  100.         and finish of sight-exposed metal.
  101.  
  102.     F.  Quality Assurance Submittals:  Contractor's certification
  103.         that installer of entrance assemblies meets specified
  104.         qualifications.
  105.  
  106.     G.  Closeout Submittals:  Operation and maintenance data for
  107.         fabricator-supplied operating hardware.
  108.  
  109.  
  110. 1.5 QUALITY ASSURANCE
  111.  
  112.     A.  Installer Qualifications:  Minimum three (3) years
  113.         installing entrance assemblies similar to that specified
  114.         in this section.
  115. NOTE ** Delete the following paragraph if not required.
  116.  
  117.     B.  Pre-Installation Meetings:
  118.         1.  Convene at job site seven (7) calendar days prior to
  119.             scheduled beginning of construction activities of
  120.             this section to review requirements of this section.
  121.         2.  Require attendance by representatives of the
  122.             following:
  123.             a.  Installer of this section.
  124.             b.  Other entities directly affecting, or affected
  125.                 by, construction activities of this section.
  126.         3.  Notify Architect four (4) calendar days in advance of
  127.             scheduled meeting date.
  128.  
  129. 1.6 DELIVERY, STORAGE, AND HANDLING
  130.  
  131.     A.  Store products of this section in fabricator's unopened
  132.         packaging until installation.
  133.  
  134. 1.7 PROJECT CONDITIONS
  135.  
  136.     A.  Field Measurements:  When construction activities permit,
  137.         take field measurements at locations to receive products
  138.         of this section; note discrepancies on submitted shop
  139.         drawings.
  140.  
  141. 1.8 SCHEDULING
  142.  
  143.     A.  Ensure that metal components to be clad, and templates
  144.         for door hardware not supplied by fabricator, are
  145.         available to fabricator of this section to allow
  146.         construction activities to proceed in accordance with
  147.         construction progress schedule.
  148.  
  149.  
  150. PART 2  PRODUCTS
  151.  
  152. 2.1 COMPONENTS
  153. NOTE ** Retain one of the following three paragraphs;
  154.         retain first if aluminum components are specified
  155.         in another section (verify section number and
  156.         coordinate within section), retain second if
  157.         aluminum components profiles and sizes are
  158.         indicated on drawings, retain third if specifying
  159.         component profiles in this section (enter required
  160.         information and delete items that do not apply).
  161.  
  162.     A.  Stile and Rail Aluminum-Framed Glass Entrances:
  163.         Specified in Section 08410; sizes indicated on drawings.
  164.  
  165.     B.  Stile and Rail Aluminum-Framed Glass Entrances:  Types
  166.         and dimensions indicated on drawings.
  167.  
  168.     C.  Stile and Rail Aluminum-Framed Glass Entrances:
  169.         1.  Door size:  __ feet __ inches (__ mm) width by __
  170.             feet __ inches (__ mm) height by __ inch (__ mm)
  171.             thickness.
  172.         2.  Stile dimension:  __ inches (__ mm).
  173.         3.  Top rail dimension:  __ inches (__ mm).
  174.         4.  Center rail dimension:  __ inches (__ mm).
  175.         5.  Bottom rail dimension:  __ inches (__ mm).
  176.         6.  Glazing provisions:  Flush stops, interior glazed.
  177.         7.  Glazing provisions:  Flush stops, exterior glazed.
  178. NOTE ** Retain one of the following three paragraphs;
  179.         retain first if aluminum components are specified
  180.         in another section (verify section number and
  181.         coordinate within section), retain second if
  182.         aluminum components profiles and sizes are
  183.         indicated on drawings, retain third if specifying
  184.         component profiles in this section (enter required
  185.         information and delete items that do not apply.)
  186.  
  187.     D.  Mullions:  Specified in Section 08410; sizes and
  188.         configurations indicated on drawings.
  189.  
  190.     E.  Mullions:  Types, configurations, and dimensions
  191.         indicated on drawings.
  192.  
  193.     F.  Mullions:
  194.         1.  Configurations:  Indicated on drawings
  195.         2.  Cross-sectional dimensions:  __ inches (__ mm) width
  196.             by __ inches (__ mm) depth.
  197.         3.  Glazing provisions:  Flush stops, interior glazed.
  198.         4.  Glazing provisions:  Flush stops, exterior glazed.
  199. NOTE ** Retain one of the following paragraphs to specify
  200.         glazing.
  201.  
  202.     G.  Glazing:  Specified in Section 08410, and as follows:
  203.         1.  Doors:  __ inch (__ mm) overall thickness.
  204.         2.  Sidelites:  __ inch (__ mm) overall thickness.
  205.  
  206.     H.  Glazing:  Specified in Section 08800, and as follows:
  207.         1.  Doors:  __ inch (__ mm) overall thickness.
  208.         2.  Sidelites:  __ inch (__ mm) overall thickness.
  209. NOTE ** Retain one of the following two paragraphs if
  210.         specifying stainless steel or brass cladding;
  211.         consult with fabricator for material specifications
  212.         if other metal is specified.  Coordinate with
  213.         REFERENCES Article of PART 1 of this section.
  214.  
  215.     I.  Cladding:
  216.         1.  Material:  Stainless steel conforming to ASTM A 666,
  217.             Type 304; ___ inch (__ mm) minimum thickness.
  218.         2.  Finish:  Number 4, satin polish.
  219.         3.  Finish:  Number 8, mirror polish.
  220. NOTE ** Delete the above sub-paragraphs specifying finish
  221.         and retain the following if specifying finish in
  222.         accordance with NAAMM Metal Finishes Manual; delete
  223.         if not required.
  224.         4.  Finish:  NAAMM designation ________________.
  225.  
  226.     J.  Cladding:
  227.         1.  Material:  Brass conforming to ASTM B 455, UNS
  228.             C28000; ___ inch (__ mm) minimum thickness.
  229.         2.  Finish:  Number 4, satin polish.
  230.         3.  Finish:  Number 8, mirror polish.
  231.         4.  Finish:  Satin oxidized oil rubbed finish.
  232.         5.  Finish:  clear baked enamel finish .
  233. NOTE ** Delete the above sub-paragraphs specifying finish
  234.         and retain the following if specifying finish in
  235.         accordance with NAAMM Metal Finishes Manual; delete
  236.         if not required.
  237.         6.  Finish:  NAAMM designation ________________.
  238.  
  239. NOTE ** Retain one of the following two paragraphs to
  240.         specify door hardware; if specifying door hardware
  241.         to be supplied by fabricator, consult fabricator
  242.         for additional information and insert into second
  243.         paragraph.
  244.  
  245.     K.  Door Hardware:  Specified in Section 08710.
  246.  
  247.     L.  Door Hardware:
  248.         1.  Supplied by fabricator as follows:
  249.             a.  Hinges:  ___________________________.
  250.             b.  Closers:  __________________________.
  251.             c.  Push/pulls:  _______________________.
  252.             d.  Locksets:  _________________________.
  253.             e.  Exit devices:  _____________________.
  254.         2.  Finish of sight-exposed metals:  Matching finish of
  255.             fittings.
  256. NOTE ** Delete the following sub-paragraph if all door
  257.         hardware to be supplied by door manufacturer.
  258.         3.  All other door hardware:  Specified in Section 08710.
  259.  
  260. 2.2 FABRICATION
  261.  
  262.     A.  Acceptable Fabricator:  ACI Distribution, located at one
  263.         of the following addresses:
  264.         1.  West of Rocky Mountains:  9010 S. Norwalk Boulevard,
  265.             Santa Fe Springs CA 90670; ASD. Tel. (800) 285-3677
  266.             or (562) 908-8893, Fax. (562) 695-8496.
  267.         2.  East of Rocky Mountains:  129000 Nicholson Road,
  268.             Farmers Branch TX 75234; ASD. Tel. (800) 284-4527 or
  269.             (972) 484-3691, Fax. (972) 247-6457.
  270. NOTE ** Delete one of the two following paragraphs;
  271.         coordinate with Division 1 requirements.
  272.  
  273.     B.  Requests for substitution will be considered in
  274.         accordance with provisions of Section 01600.
  275.  
  276.     C.  Substitutions:  Not permitted.
  277.  
  278.     D.  Shop Assembly:
  279.         1.  Clad aluminum components with specified cladding
  280.             materials, forming flat surfaces and edges of
  281.             cladding materials to fit tight to aluminum surfaces.
  282.         2.  Locate seams in cladding materials in accordance with
  283.             shop drawings, forming straight hairline-width butt
  284.             joints.
  285.         3.  Permanently laminate cladding materials to aluminum
  286.             surfaces; visible fastening devices not permitted.
  287.         4.  Prepare clad components for specified hardware.
  288.         5.  Finish surfaces of cladding materials to specified
  289.             finish; apply strippable protective materials to
  290.             finished surfaces.
  291.         6.  Assemble components to extent practical, considering
  292.             shipping limitations.
  293.  
  294.  
  295. PART 3  EXECUTION
  296.  
  297. 3.1 EXAMINATION
  298.  
  299.     A.  Verify that openings to receive entrance assemblies are
  300.         of correct size and are prepared correctly, in accordance
  301.         with shop drawings.
  302.  
  303.     B.  Installer's Examination:
  304.         1.  Have installer of this section examine conditions
  305.             under which construction activities of this section
  306.             are to be performed, then submit written notification
  307.             if such conditions are unacceptable.
  308.         2.  Transmit two copies of installer's report to
  309.             Architect within 24 hours of receipt.
  310.         3.  Beginning construction activities of this section
  311.             before unacceptable conditions have been corrected is
  312.             prohibited.
  313.         4.  Beginning construction activities of this section
  314.             indicates installer's acceptance of conditions.
  315.  
  316. 3.2 INSTALLATION
  317. NOTE ** Delete references to related construction
  318.         activities of other sections that do not apply to
  319.         project; add others as applicable to project.
  320.         Coordinate with RELATED SECTIONS Article of PART 1
  321.         of this section.
  322.  
  323.     A.  Install entrance assembly components in accordance with
  324.         shop drawings.
  325.  
  326.     B.  Remove strippable protective materials from metal
  327.         surfaces only to extent required for installation of
  328.         assembly, and to receive glazing and door hardware.
  329. NOTE ** Retain one of the following two sub-paragraphs;
  330.         retain first if requiring installer of this section
  331.         to install glazing, retain second if all glazing is
  332.         installed under Section 08800.
  333.  
  334.     C.  Install glazing in accordance with installation
  335.         requirements of Section 08800, and shop drawings.
  336.  
  337.     D.  Installation of glazing is specified in Section 08800.
  338. NOTE ** Retain one or more of the following three sub-
  339.         paragraphs; retain first if all door hardware is
  340.         specified in Section 08710, retain second if
  341.         requiring all or some door hardware on doors in
  342.         this section to be installed by installer of this
  343.         section, retain third if door hardware, other than
  344.         supplied by door manufacturer, is specified in
  345.         Section 08710.
  346.  
  347.     E.  Installation of door hardware is specified in Section
  348.         08710.
  349.  
  350.     F.  Install fabricator-supplied door hardware in accordance
  351.         with installation requirements of Section 08710, shop
  352.         drawings, and door hardware manufacturers' instructions.
  353.  
  354.     G.  Installation of other door hardware is specified in
  355.         Section 08710.
  356.  
  357.     H.  Site Tolerances:
  358.         1.  Variation from level, horizontal components and sight
  359.             lines:  1/8 inch in 10 feet (3 mm in 3 m), non-
  360.             cumulative.
  361.         2.  Variation from plumb, vertical components and sight
  362.             lines:  1/8 inch in 10 feet (3 mm in 3 m), non-
  363.             cumulative.
  364.         3.  Variation from plane, installed assembly:  Maximum
  365.             1/16 inch (1.5 mm)
  366.  
  367. 3.3 ADJUSTING
  368.  
  369.     A.  Adjust entrance doors to swing correctly, without binding
  370.         to frame, sill, or adjacent doors.
  371. NOTE ** Retain the following sub-paragraph if installation
  372.         of door hardware is specified in this section.
  373.  
  374.     B.  Adjust door hardware to operate correctly.
  375.  
  376. 3.4 CLEANING
  377.  
  378.     A.  Immediately prior to Substantial Completion, remove
  379.         strippable protective materials from metal surfaces;
  380.         clean metal surfaces free of adhesive residue and other
  381.         foreign substances, using cleaning materials and methods
  382.         recommended by fabricator of this section.
  383.  
  384. 3.5 PROTECTION
  385.  
  386.     A.  Protect finished installation from damage by subsequent
  387.         construction activities until Substantial Completion.
  388.  
  389.     B.  Repair components damaged by subsequent construction
  390.         activities in accordance with fabricator's
  391.         recommendations; replace damaged components that cannot
  392.         be repaired to Architect's acceptance.
  393.  